Determination of chlorpropham (CIPC) residues, in the concrete flooring of potato stores, using quantitative (HPLC UV/VIS) and qualitative (GCMS) methods.
Clicks: 266
ID: 42993
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
67.4
/100
266 views
175 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #200 of 409 articles by views in Chemosphere
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 409 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Isopropyl-N-(3-chlorophenyl) carbamate (CIPC, common name Chlorpropham) is commonly used for post-harvest sprout inhibition in stored potatoes. It is applied as a thermal fog which results in loss to the fabric of the store and the atmosphere. Recently, there have been concerns in the United Kingdom because of cross contamination of other crop commodities that were stored in buildings with a history of CIPC usage. This cross contamination may have occurred because of retained residues in the fabric of the stores. The retention of CIPC in concrete is poorly understood; therefore the requirement for a robust analytical method for the detection and quantification of CIPC in concrete is a critical first step in tackling this problem. A method using High-Performance Liquid Chromatography with ultraviolet detection (HPLC UV/VIS) was validated. CIPC recoveries at three concentration levels (0.4, 4.0 and 40.0 μg g) were in the range of 90.7-97.0% with relative standard deviations between 2.14 and 3.01%. The limits of detection and quantification were 0.03 and 0.1 μg g, respectively. This study confirmed that CIPC was persistent in concrete to a depth of 4 cm, with >90% within the top 1 cm of the flooring.
| Reference Key |
douglas2018determinationchemosphere
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Douglas, Leisa;MacKinnon, Gillian;Cook, Gordon;Duncan, Harry;Briddon, Adrian;Seamark, Steven; |
| Journal | Chemosphere |
| Year | 2018 |
| DOI |
S0045-6535(17)31971-9
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.