A new mobile self-dispensing and administering system for 18F-FDG: evaluation of operator dose reduction.
Clicks: 344
ID: 42193
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
344 views
93 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #11 of 16 articles by views in journal of radiological protection : official journal of the society for radiological protection
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Recently new mobile systems for dispensing positron emitters were produced, designed to guarantee dispensing cycles in an aseptic environment. The aim of the present work was to assess the advantage of one of these systems in radiation protection of operators in clinical setting. METHODS: Recently, in our centre the new self-dispensing system named KARL100 by Tema Sinergie was adopted for 18F-FDG radiopharmaceuticals. The system is associated with an automatic Rad-inject infuser. The system previously used was a fixed isolator NMC DSI (Tema Sinergie), equipped with a µDDS-An activity fractioning system, together with a pneumatic post for the syringe delivery. The dosimetric evaluations on both systems were carried out through environmental measurements with an ionization chamber and with the use of personal dosimeters. RESULTS: The operations of preparation and administration of 18F-FDG dose to the patient, with the use of Karl100 + RadInject, involve exposures much lower than those obtained by the fixed isolator. The average body exposure of technician was reduced by 31%, and for the physician by 77%. On the extremities, the equivalent dose to the hands of the technician was reduced by 78% and for the physician by 96%. Also the additional dosimeters worn by the technician confirmed the estimated environmental assessments. CONCLUSIONS: The exposures of the working personnel were significantly reduced with the introduction of the new KARL100 system. 
.
| Reference Key |
ferretti2019ajournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ferretti, Alice;Massaro, Arianna;Gusella, Stella;Rampin, Lucia;Maffione, Anna Margherita;Chondrogiannis, Sotirios;Marzola, Maria Cristina;Grassetto, Gaia;Delgado-Bolton, Roberto;Rubello, Domenico;Gava, Marcello; |
| Journal | journal of radiological protection : official journal of the society for radiological protection |
| Year | 2019 |
| DOI |
10.1088/1361-6498/ab4287
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.