Testing heart rate asymmetry in long, nonstationary 24-hour RR-intervals time series.
Clicks: 340
ID: 42192
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
340 views
35 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #10 of 16 articles by views in physiological measurement
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Heart rate asymmetry is an unequal and unidirectional phenomenon where the contribution of heart rate decelerations to short-term heart rate variability is greater than that of accelerations, and the contribution of accelerations to long-term and total variability is greater than that of deceleration. This has been established for short, stationary recordings. In this paper, we analyse heart rate asymmetry in 87 long, 24-hour ECG Holter recordings from healthy people. We show that in the whole recording all types of asymmetry are observable, clear and highly statistically significant. To analyse the local changes of asymmetry in time, we analyzed the recordings by disjoint jumping windows of 300-beats. This analysis revealed that also the local, averaged measures of all types of asymmetry demonstrate its presence which is highly statistically significant. Additionally, we introduce in this paper a statistical test for asymmetry in the single long recording, as opposed to the current approach in which the whole groups are tested. We do so by introducing the proportion of time spent in asymmetry for each recording and using it in the binomial tests. We found that for all the recordings most of the time is spent in asymmetry.
| Reference Key |
piskorski2019testingphysiological
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Piskorski, Jaroslaw;Ellert, Jerzy;Krauze, Tomasz;Grabowski, Waldemar;Wykretowicz, Andrzej;Guzik, Przemyslaw; |
| Journal | physiological measurement |
| Year | 2019 |
| DOI |
10.1088/1361-6579/ab42d5
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.