Selective Spleen Scintigraphy in the Evaluation of Accessory Spleen/Splenosis in Splenectomized/Nonsplenectomized Patients and the Contribution of SPECT Imaging.
Clicks: 441
ID: 4208
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
85.0
/100
441 views
330 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 32 articles by views in molecular imaging and radionuclide therapy
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
We aimed to evaluate the results of selective spleen scintigraphy (SSS) and contribution of SPECT imaging to planar imaging in splenectomized and nonsplenectomized patients.We retrospectively examined 112 SSSs of 96 patients. The patients were divided into two groups as splenectomized group (SP) and non-splenectomized group (NSP). The findings were evaluated by comparing the results of surgery,computerized tomography (CT), ultrasonography (USG) and magnetic resonance imaging (MRI). In addition, whether or not differences existed between the results of SPECT and planar imaging was determined.Of 66 scintigraphies performed in the NSP group, 3 (5%) had positive, 3 (5%) had suspicious and 60 (90%) had negative results. In the NSP group, 28 patients underwent surgery and 12 accessory spleens were removed. Only 3 of these tissues were detected by scintigraphy. Of 46 patients in the SP group, 26 (57%) had positive findings whereas 20 (43%) had negative scintigraphies. Twelve accessory spleens/splenosis were removed surgically in 10 patients with a positive SSS in the SP group. There were no false positive results in both groups of patients who underwent surgery. There was no significant difference between the results of SSS, USG and CT. Of 39 patients to whom SPECT were performed, 10 had positive results both with planar and SPECT imaging. On the other hand, 26 patients, 3 of whom had suspected findings in SPECT images, demonstrated negative results when evaluated with both imaging methods. Remaining 3 were considered suspicious by only SPECT images for the hilar area.SSS has high specificity in the detection of accessory spleens/splenosis. The sensitivity of SSS is low in the NSP group,but higher in the SP group. There is no contribution of SPECT imaging to planar imaging.
| Reference Key |
ekmekci2015selectivemolecular
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ekmekçi, Şeyma;Diz-Küçükkaya, Reyhan;Türkmen, Cüneyt;Adalet, Işık; |
| Journal | molecular imaging and radionuclide therapy |
| Year | 2015 |
| DOI |
10.4274/mirt.40085
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.