Chromatographic determination of 12 dyes in meat products by HPLC-UV-DIODE array detection.

Clicks: 178
ID: 41916
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #30 of 70 articles by views in methodsx

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The use of food dyes in meat is regulated by the current European and non-European legislation, due to several food safety concerns. A reliable method for the quali-quantitative determination of 12 food dyes (Amaranth, Ponceau 4R, Carmine, Ponceau SX, Ponceau 3R, Allura Red AC, Carmoisine, Erythrosine, Sudan I, Sudan II, Sudan III and Sudan IV) in meat products, by high performance liquid chromatography coupled to UV diode array detection is presented. The extraction was accomplished by using acetonitrile, methanol, water, and ammonia, 50:40:9:1 (v/v/v/v) as the solvent and ultrasonic bath. The chromatographic separation was obtained with a C RP column eluted by a gradient of acetate buffer/acetonitrile. Good analytical performances characterized this method (Table 1), in terms of selectivity, sensitivity, accuracy and ruggedness. Both method precision (CV% range: 6%-15%) and recovery percentages (range: 86%-105%) resulted in compliance with Decision 2002/657/EC, and the expanded measurement uncertainties, estimated by a bottom-up approach, were in the range 6%-20%. All these results demonstrated that the procedure can be applied successfully for confirmation analyses of commercial meat products. •12 food dyes were determined in meat by new HPLC/UV-DAD method.•The analytical method was fully validated for accurate confirmation analyses.•Method accuracy, sensitivity, selectivity and ruggedness resulted satisfactory.
Reference Key
iammarino2019chromatographicmethodsx Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Iammarino, Marco;Mentana, Annalisa;Centonze, Diego;Palermo, Carmen;Mangiacotti, Michele;Chiaravalle, Antonio Eugenio;
Journal methodsx
Year 2019
DOI
10.1016/j.mex.2019.04.018
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.