The Influence of Aerosol Density and Shape Factor on the Assessment of Internal Exposure to 239Pu.
Clicks: 188
ID: 41635
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
188 views
19 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #11 of 18 articles by views in health physics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Internal exposure due to inhalation of aerosols depends on the ratio of aerodynamic shape factor (χ) to aerosol mass density (ρ). Inhaled aerosol parameters may differ from the default ρ and χ values provided by the International Commission on Radiological Protection, which are adopted for the assessment of internal exposures. This paper focuses on the influences of χ/ρ on the assessment of internal exposure to Pu for reference workers. Regional deposition fractions are found to decrease with increasing χ/ρ, and larger decreases are observed with smaller activity median aerodynamic diameter aerosols, while the slow clearance fractions (fs) in the tracheobronchial region are more sensitive for larger activity median aerodynamic diameter aerosols. Results from biokinetics calculations reveal that both the time-dependent content (excretion) and cumulative activities are determined mainly for particles initially deposited in the alveolar-interstitial region, while fs affects the local cumulative activities in the tracheobronchial region. χ/ρ is proven to have different influences for aerosols with different activity median aerodynamic diameters. The default χ/ρ values can be used when activity median aerodynamic diameters are greater than 1 μm, while one should pay attention to the value of χ/ρ when activity median aerodynamic diameters are less than 1 μm, where significant influence may be anticipated.
| Reference Key |
zhang2019thehealth
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Zhang, Bin;Sheng, Wei;Xu, Ming;Zhang, Yang;Lei, Jie-Ying;Ma, Huai-Cheng; |
| Journal | health physics |
| Year | 2019 |
| DOI |
10.1097/HP.0000000000001052
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.