Evaluation of a deep learning-based pelvic synthetic CT generation technique for MRI-based prostate proton treatment planning.

Clicks: 273
ID: 41137
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #27 of 37 articles by views in Physics in medicine and biology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The purpose of this work is to validate the application of a deep learning-based method for pelvic synthetic CT (sCT) generation that can be used for prostate proton beam therapy treatment planning. We propose to integrate dense block minimization into 3D cycle-consistent generative adversarial networks (cycle GAN) framework to effectively learn the nonlinear mapping between MRI and CT pairs. A cohort of 17 patients with co-registered CT and MR pairs were used to test the deep learning-based sCT generation method by leave-one-out cross-validation. Image quality between the sCT and CT images, gamma analysis passing rate, dose-volume metrics, distal range displacement, and the individual pencil beam Bragg peak shift between sCT- and CT-based proton plans were evaluated. The average mean absolute error (MAE) was 51.32±16.91 HU. The relative differences of the statistics of the PTV dose volume histogram (DVH) metrics in between sCT and CT were generally less than 1%. Mean values of dose difference, absolute dose difference (in percent of prescribed dose) were -0.07±0.07% and 0.23±0.08%. Mean gamma analysis pass rate of 1mm/1%, 2mm/2%, 3mm/3% criteria with 10% dose threshold were 92.39±5.97%, 97.95±2.95% and 98.97±1.62% respectively. The median, mean and standard deviation of absolute maximum range differences were 0.09 cm and 0.23±0.25 cm. The median and mean Bragg peak shifts among the 17 patients were 0.09 cm and 0.18±0.07 cm. The image similarity, dosimetric and distal range agreement between sCT and original CT suggests the feasibility of further development of an MRI-only workflow for prostate proton radiotherapy.
Reference Key
liu2019evaluationphysics Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Physics in medicine and biology
Year 2019
DOI
10.1088/1361-6560/ab41af
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.