Mobile Platform for Multiplexed Detection and Differentiation of Disease-Specific Nucleic Acid Sequences, Using Microfluidic Loop-Mediated Isothermal Amplification and Smartphone Detection.
Clicks: 282
ID: 40859
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
71.0
/100
282 views
230 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #45 of 194 articles by views in Analytical chemistry
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 194 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
New tools are needed to enable rapid detection, identification, and reporting of infectious viral and microbial pathogens in a wide variety of point-of-care applications that impact human and animal health. We report the design, construction, and characterization of a platform for multiplexed analysis of disease-specific DNA sequences that utilizes a smartphone camera as the sensor in conjunction with a hand-held "cradle" that interfaces the phone with a silicon-based microfluidic chip embedded within a credit-card-sized cartridge. Utilizing specific nucleic acid sequences for four equine respiratory pathogens as representative examples, we demonstrated the ability of the system to utilize a single 15 μL droplet of test sample to perform selective positive/negative determination of target sequences, including integrated experimental controls, in approximately 30 min. Our approach utilizes loop-mediated isothermal amplification (LAMP) reagents predeposited into distinct lanes of the microfluidic chip, which when exposed to target nucleic acid sequences from the test sample, generates fluorescent products that when excited by appropriately selected light emitting diodes (LEDs), are visualized and automatically analyzed by a software application running on the smartphone microprocessor. The system achieves detection limits comparable to those obtained by laboratory-based methods and instruments. Assay information is combined with the information from the cartridge and the patient to populate a cloud-based database for epidemiological reporting of test results.
| Reference Key |
chen2017mobileanalytical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Chen, Weili;Yu, Hojeong;Sun, Fu;Ornob, Akid;Brisbin, Ryan;Ganguli, Anurup;Vemuri, Vinay;Strzebonski, Piotr;Cui, Guangzhe;Allen, Karen J;Desai, Smit A;Lin, Weiran;Nash, David M;Hirschberg, David L;Brooks, Ian;Bashir, Rashid;Cunningham, Brian T; |
| Journal | Analytical chemistry |
| Year | 2017 |
| DOI |
10.1021/acs.analchem.7b02478
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.