A simultaneously quantitative profiling method for 40 endogenous amino acids and derivatives in cell lines using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry
Clicks: 310
ID: 40748
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
74.0
/100
310 views
255 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #49 of 391 articles by views in Talanta
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 391 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
It is very necessary to develop real-time, highly sensitive and selective fluorescent probes for hypochlorite (ClO) in living cells owing to hypochlorite's important role in pathological and physiological processes and its short life. Herein, a pyrene Schiff's base derivative was successfully developed for real-time (within seconds), highly sensitive detecting ClO with a low detection limit (5.7 nM) and wide pH range (4.0-11.0) based on nucleophilic addition and subsequent hydrolysis mechanism. The probe has aggregation-induced emission properties and emits yellow fluorescence (544 nm) in PBS solution, while it exhibits blue fluorescence in other organic solvents (426 nm (THF) - 460 nm (MeOH)). The probe can be used to response ClO in A549 cells with low cytotoxicity, a good cell membranes penetration and good biocompatibility. Cell uptake experiment indicates that probe getting into the cells is energy-dependent and is not attributed to endocytosis. Moreover, the probe is successfully used in real water sample to detect ClO and it can be expected to be applied to ClO participated biological and pathological functions in biological systems.
| Reference Key |
zhu2020atalanta
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Zhu, B. |
| Journal | Talanta |
| Year | 2020 |
| DOI |
10.1016/j.talanta.2019.120256
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.