Acoustic source localization in a highly anisotropic plate with unknown orientation of its axes of symmetry and material properties with numerical verification.
Clicks: 346
ID: 40345
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
346 views
39 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #3 of 19 articles by views in ultrasonics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Development of acoustic source localization techniques in anisotropic plates has gained attention in the recent past and still has scope of improvement. Most of such techniques existing in the literature either require known material properties or assume a straight line propagation of wave energy from the acoustic source to a sensor. These limitations have been overcome in recent years by employing wave front shape-based techniques. However, the existing wave front shape-based techniques are applicable in situations where the orientation of the axes of symmetry of the anisotropic plate is known beforehand. In the present study, a modified version of these techniques, namely, elliptical and parametric curve-based techniques, is proposed. This new version is useful when the angle between the axes of symmetry and the reference Cartesian coordinate system is unknown. In the new definition of the objective function, the orientation of the axes of symmetry of the anisotropic plate is treated as an input in the objective function in addition to the other unknowns like the source coordinates and the curve parameters. A numerical study illustrates how the modified new techniques can localize the acoustic source with sufficient accuracy in an anisotropic plate with unknown orientation of the axes of symmetry and its material properties.
| Reference Key |
sen2019acousticultrasonics
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Sen, Novonil;Kundu, Tribikram; |
| Journal | ultrasonics |
| Year | 2019 |
| DOI |
S0041-624X(19)30203-3
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.