Health Monitoring of Metallic Structures with Electromechanical Impedance and Piezoelectric Sensors.

Clicks: 191
ID: 40344
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #290 of 331 articles by views in Nanomaterials

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 331 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
In order to monitor the health condition of structures in a more sensitive and accurate way, a novel and universal methodology called direct coupling mechanical impedance (DCMI) for characteristic signatures extraction is presented in this paper. This methodology is used to obtain DCMI signatures from measured raw signatures (RSs) with the surface-bonded piezoelectric sensors (PZT), which is developed from a pertinent electromechanical impedance (EMI) theoretical model for surface-bonded circular PZT. The proposed DCMI methodology has the advantages of simple calculation and magnifying the signatures when compared with the existing methods. Combining the extracted DCMI signatures with the root mean square deviation (RMSD) index is able to quantify the correlation between the health condition and the signatures variation more effectively. To verify the effectiveness of proposed DCMI methodology, experiments are conducted on aluminum plates and a part of fuselage in detail. The experimental results sufficiently demonstrate that the presented universal DCMI methodology possesses better sensitivity than the raw signatures when utilized for evaluating the health condition of metallic structures, including those made of metal-matrix nanomaterials.
Reference Key
zhu2019healthnanomaterials Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Zhu, Jianjian;Wang, Yishou;Qing, Xinlin;
Journal Nanomaterials
Year 2019
DOI
E1268
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.