Three-dimensional microfluidic paper-based device for multiplexed colorimetric detection of six metal ions combined with use of a smartphone.

Clicks: 298
ID: 3992
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #28 of 90 articles by views in Analytical and bioanalytical chemistry

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A simple double-layered three-dimensional (3D) microfluidic paper-based analytical device (μPAD) was designed for the simultaneous determination of six metal ions-Fe(III), Ni(II), Cr(VI), Cu(II), Al(III), and Zn(II)-for the first time. The 3D μPAD was composed of two paper layers: a top pretreatment layer and a bottom colorimetric detection layer. The sample solution added to the central sample reservoir of the 3D μPAD could be automatically divided into eight flow pathways and be automatically pretreated while flowing through the pretreatment zones located in the microfluidic channels, and automatically carried out the chromogenic reactions after reaching the detection zones. Random diffusion of the chromogenic reagents was effectively prevented by transport of the pretreated sample solution to the detection zones through 3D microfluidic channels with an L-type circuitous flow route design, resulting in highly increased color uniformity and reproducibility. Combined with use of a flat LED lamp as an upward lighting source and a smartphone as a convenient detector, improved color perception, highly enhanced sensitivity, and an extended detection range were obtained. Finally, the double-layered 3D μPAD was applied to the multiplexed determination of the six metal ions in mixtures and environmental samples with satisfactory results. Detection limits as low as 0.2, 0.3, 0.1, 0.03, 0.08, and 0.04 mg/L for Fe(III), Ni(II), Cr(VI), Cu(II), Al(III), and Zn(II) detection, respectively, were achieved, which are about one order of magnitude lower than obtained with previously reported μPADs for the detection of metal ions. The present 3D μPAD is simple, fast, selective, sensitive, and user-friendly, and holds great application potential for multiplexed on-site analysis.
Reference Key
li2019threedimensionalanalytical Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Li, Fang;Hu, Yuting;Li, Zimu;Liu, Jiachang;Guo, Lei;He, Jianbo;
Journal Analytical and bioanalytical chemistry
Year 2019
DOI
10.1007/s00216-019-02032-5
URL
Keywords Keywords not found