Infrared (IR) thermography as a potential screening modality for carotid artery stenosis.
Clicks: 230
ID: 39877
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
230 views
29 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #26 of 87 articles by views in Computers in biology and medicine
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In the present study, an infrared (IR) thermal camera was used to map the temperature of the target skin surface, and the resulting thermal image was evaluated for the presence of carotid artery stenosis (CAS). In the presence of stenosis in the carotid artery, abnormal temperature maps are expected to occur on the external skin surface, which could be captured and quantified using IR thermography. A Duplex Ultrasound (DUS) examination was used to establish the ground truth. In each patient, the background-subtracted thermal image, referred to as full thermal image, was used to extract novel parametric cold thermal feature images. From these images, statistical features, viz., correlation, energy, homogeneity, contrast, entropy, mean, standard deviation (SD), skewness, and kurtosis, were calculated and the two groups of patients (control and diseased: a total of 80 carotid artery samples) were classified. Both cut-off value- and support vector machine (SVM)-based binary classification models were tested. While the cut-off value classification model resulted in a moderate performance (70% accurate), SVM was found to have classified the patients with high accuracy (92% or higher). This preliminary study suggests the potential of IR thermography as a possible screening tool for CAS patients.
| Reference Key |
saxena2019infraredcomputers
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Saxena, Ashish;Ng, E Y K;Lim, Soo Teik; |
| Journal | Computers in biology and medicine |
| Year | 2019 |
| DOI |
S0010-4825(19)30296-3
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.