In situ immobilization of sulfated-β-cyclodextrin as stationary phase for capillary electrochromatography enantioseparation.
Clicks: 267
ID: 39304
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
72.8
/100
267 views
218 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #106 of 391 articles by views in Talanta
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 391 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In this work, a novel sulfated-β-cyclodextrin (S-β-CD) coated stationary phase was prepared for open-tubular capillary electrochromatography (OT-CEC). The capillary was developed by attaching polydopamine/sulfated-β-cyclodextrin (PDA/S-β-CD) onto the gold nanoparticles (AuNPs) coated capillary which was pretreated with polydopamine. The results of scanning electron microscopy (SEM) and energy dispersive X-ray analysis spectroscopy (EDS) indicated that polydopamine/sulfated-β-cyclodextrin was successfully fixed on the gold nanoparticles coated capillary. To evaluate the performance of the prepared open tubular (OT) column, the enantioseparation was carried out by using ten chiral drugs as model analytes. Under the optimal conditions, salbutamol, terbutaline, trantinterol, tulobuterol, clorprenaline, pheniramine, chlorpheniramine, brompheniramine, isoprenaline and tolterodine were baseline separated with the resolution (Rs) values of 3.25, 1.76, 2.51, 1.89, 3.17, 2.17, 1.99, 1.72, 2.01 and 3.20, respectively. Repeatability of the column was studied, with the relative standard deviations for run-to-run, day-to-day and column-to-column lower than 5.7%.
| Reference Key |
zhou2019intalanta
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Zhou, Li;Lun, Jia;Liu, Yanru;Jiang, Zhen;Di, Xin;Guo, Xingjie; |
| Journal | Talanta |
| Year | 2019 |
| DOI |
S0039-9140(19)30276-0
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.