A Flexible, Robust, and Gel-Free Electroencephalogram Electrode for Noninvasive Brain-Computer Interfaces.

Clicks: 297
ID: 38705
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #23 of 275 articles by views in Nano letters

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 275 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Brain-computer interfaces (BCIs) enable direct and near-instant communication between the brain and electronic devices. One of the biggest remaining challenges is to develop an effective noninvasive BCI that allows the recording electrodes to avoid hair on human skin without the inconveniences and complications of using a conductive gel. In this study, we developed a cost-effective, easily manufacturable, flexible, robust, and gel-free silver nanowire/polyvinyl butyral (PVB)/melamine sponge (AgPMS) electroencephalogram (EEG) electrode that circumvents problems with hair. Because of surface metallization by the silver nanowires (AgNWs), the sponge has a high conductivity of 917 S/m while its weight remains the same. The flexible sponge framework and self-locking AgNWs combine to give the new electrode remarkable mechanical stability (the conductivity remains unchanged after 10 000 cycles at 10% compression) and the ability to bypass hair. A BCI application based on steady-state visual evoked potential (SSVEP) measurements on hairless skin shows that the BCI accuracy of the new electrode (86%) is approximately the same as that of conventional electrodes supported by a conductive gel (88%). Most importantly, the performance of the AgPMS on hairy skin is not significantly reduced, which indicates that the new electrode can replace conventional electrodes for both hairless and hairy skin BCIs and other EEG applications.
Reference Key
lin2019anano Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Lin, Sen;Liu, Junchen;Li, Wenzheng;Wang, Dong;Huang, Ya;Jia, Chao;Li, Ziwei;Murtaza, Muhammad;Wang, Haiyang;Song, Jianan;Liu, Zhenglian;Huang, Kai;Zu, Di;Lei, Ming;Hong, Bo;Wu, Hui;
Journal Nano letters
Year 2019
DOI
10.1021/acs.nanolett.9b02019
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.