Multi optimized SVM classifiers for motor imagery left and right hand movement identification.

Clicks: 303
ID: 38693
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #8 of 8 articles by views in australasian physical & engineering sciences in medicine

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
EEG signal can be a good alternative for disabled persons who cannot perform actions or perform them improperly. Brain computer interface (BCI) is an attractive technology which permits control and interaction with a computer or a machine using EEG signals. Brain task identification based on EEG signals is very difficult task and is still challenging researchers. In this paper, the motor imagery of left and right hand actions are identified using new features which are fed to a set of optimized SVM classifiers. Multi classifiers based classification showed having high faculty to improve the classification accuracy when using different kind or diversified features. Features selection was performed by genetic algorithm optimization. In single optimized SVM classifier, a mean classification accuracy of 89.8% was reached. To further improve the rate of classification, three SVMs classifiers have been suggested and optimized in order to find suitable features for each classifier. The three SVMs classifiers were optimized and achieved a performance mean of 94.11%. The achieved performance is a significant improvement comparing to the existing methods which does not exceed 81% while using the same database. Here, combining multi classifiers with selecting suitable features by optimization can be a good alternative for BCI applications.
Reference Key
mebarkia2019multiaustralasian Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Mebarkia, Kamel;Reffad, Aicha;
Journal australasian physical & engineering sciences in medicine
Year 2019
DOI
10.1007/s13246-019-00793-y
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.