Response characteristics of ship steam power system under switchover of turbine feed water pump
Clicks: 416
ID: 37356
0000
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
83.6
/100
416 views
309 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #2 of 2 articles by views in zhongguo jianchuan yanjiu
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
[Objectives] The switching performance of turbine feed water pump is a key technical indicator to decide the operation stability of ship steam power system, and it is of great significance to the safety of navigation.[Methods] Using the Modular Modeling System(MMS) thermal engineering system simulation software, a simulation model of ship steam turbine power system based on the switching principle of turbine feed water pump is established. Meanwhile, the accuracy of the simulation model is verified by experiment data. The dynamic response of turbine feed water pump to steam-water cycle of steam turbine power system is analyzed under high-speed and low-speed conditions.[Results] The calculation results show that switchover of turbine feed water pump can meet the water supply demand of supercharged boiler under high-speed and low-speed conditions. After switching, the system can run stably under low-speed condition, but the operation of the system is unstable after switching under high-speed condition. It shows that the water level of the condenser rapidly rises to an extremely high level, and the water level of the deaerator drops sharply to an extremely low level. Severe pressure fluctuation occurs in exhaust steam and micro superheated steam.[Conclusions] The research results can provide theoretical support for the optimization of the switching scheme of the steam turbine feed water pump.
| Reference Key |
yuanlong0000responsezhongguo
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Yuanlong, Yang;Jinxiang, Wu;Zidu, Zheng;Wei, Wu;Ling, Sun; |