Accuracy and precision of USCOM versus transthoracic echocardiography before and during pregnancy.

Clicks: 302
ID: 37302
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #3 of 6 articles by views in pregnancy hypertension

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Monitoring hemodynamic status throughout pregnancy may help in identifying women with maladaptation predisposing to hypertensive complications. The Ultrasonic Cardiac Output Monitor (USCOM) is an easy-to-operate device for measuring cardiac output (CO) quickly. Our aim was to assess agreement between USCOM and transthoracic echocardiography (TTE) in: 1) non-pregnant women to correct for possible sources of discrepancy; 2) women longitudinally over the course of the pregnancy.High-risk women admitted for cardiovascular risk factor evaluation before pregnancy and multiple times during pregnancy, were included. CO was measured by TTE directly followed by USCOM measurements.Bias, limits of agreement (LOA) and percentage error between the two methods by Bland-Altman analysis.Despite comparable non-pregnant CO levels (4.6 L/min), LOA and percentage error between the two methods improved moderately by optimizing the measurements using only the highest quality USCOM recordings in 132 non-pregnant women (percentage error of 39% and 30%, respectively). During pregnancy, in total 83, 106, 96 and 77 measurements were evaluated at respectively 12, 16, 20 and 30 weeks gestational age. Mean CO in USCOM was about 0.6 L/min higher compared to TTE in all trimesters; percentage error ranged from 35% to 45%. Linear mixed model analysis showed no association between bias and moment of measurement.Agreement between USCOM and TTE in pregnancy was outside our a priori determined level of acceptability and therefore absolute values of USCOM and TTE cannot be used interchangeably. Future research should focus on the agreement of USCOM and TTE in clinical decision-making.
Reference Key
mulder2019accuracypregnancy Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Mulder, Eva;Basit, Shumalla;Oben, Jolien;van Kuijk, Sander;Ghossein-Doha, Chahinda;Spaanderman, Marc;
Journal pregnancy hypertension
Year 2019
DOI
S2210-7789(18)30707-4
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.