Core/Shell Piezoelectric Nanofibers with Spatial Self-Orientated β-Phase Nanocrystals for Real-Time Micropressure Monitoring of Cardiovascular Walls.
Clicks: 415
ID: 37125
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
66.8
/100
415 views
299 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #11 of 150 articles by views in acs nano
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 150 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Implantable pressure biosensors show great potential for assessment and diagnostics of pressure-related diseases. Here, we present a structural design strategy to fabricate core/shell polyvinylidene difluoride (PVDF)/hydroxylamine hydrochloride (HHE) organic piezoelectric nanofibers (OPNs) with well-controlled and self-orientated nanocrystals in the spatial uniaxial orientation (SUO) of β-phase-rich fibers, which significantly enhance piezoelectric performance, fatigue resistance, stability, and biocompatibility. Then PVDF/HHE OPNs soft sensors are developed and used to monitor subtle pressure changes . Upon implanting into pig, PVDF/HHE OPNs sensors demonstrate their ultrahigh detecting sensitivity and accuracy to capture micropressure changes at the outside of cardiovascular walls, and output piezoelectric signals can real-time and synchronously reflect and distinguish changes of cardiovascular elasticity and occurrence of atrioventricular heart-block and formation of thrombus. Such biological information can provide a diagnostic basis for early assessment and diagnosis of thrombosis and atherosclerosis, especially for postoperative recrudescence of thrombus deep within the human body.
| Reference Key |
li2019coreshellacs
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Li, Tong;Feng, Zhang-Qi;Qu, Minghe;Yan, Ke;Yuan, Tao;Gao, Bingbing;Wang, Ting;Dong, Wei;Zheng, Jie; |
| Journal | acs nano |
| Year | 2019 |
| DOI |
10.1021/acsnano.9b02483
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.