Performance Analysis of a Microfluidic Pump Based on Combined Actuation of the Piezoelectric Effect and Liquid Crystal Backflow Effect.
Clicks: 310
ID: 37115
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
72.0
/100
310 views
208 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #27 of 128 articles by views in micromachines
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 128 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A novel combined actuation method based on the piezoelectric effect and liquid crystal backflow effect is proposed in this paper. The coupling mechanism of a piezoelectric transducer (PZT) and liquid crystal (LC) in a combined driving mode is analyzed, and the governing equations of electromechanical coupling based on inverse piezoelectric effect and the classical Leslie-Ericksen backflow equation are modified under combined driving method. The new multifield coupling dynamic equations for numerical analysis is established. Experimentally, a sandwiched micropump was manufactured and sealed with wet etching technology on a glass wafer. A testing platform was built to analyze the particles motion and the flow rates were measured with both single PZT or LC actuation and combined actuation. Comparing the results of the numerical analysis and experimental testing of the flow rate and LC molecule motion under different driving voltages and frequencies, the performance of the PZT/LC combined driving is found to be superior to that of the single driving mode (PZT or LC driving) under the same driving conditions. Moreover, the new combined driving mode overcome the disadvantages of single driving mode and enhance the driving efficiency significantly. The simulation results are in good agreement with the experimental data. The maximum flow rate of the micropump achieved was 4.494 μL/min with combined driving method.
| Reference Key |
guan2019performancemicromachines
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Guan, Yanfang; |
| Journal | micromachines |
| Year | 2019 |
| DOI |
E584
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.