Limited Urethral Mobilization Technique in Distal Hypospadias Repair with Satisfactory Results
Clicks: 411
ID: 37059
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
69.9
/100
411 views
299 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #3 of 85 articles by views in balkan medical journal
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Objective: To assess the outcomes of the Limited Urethral Mobilization (LUM) technique in distal hypospadias repair.Material and Methods: Forty-seven patients, who were operated on with the LUM technique iduring a 6 years period, were grouped according to their ages. Age distribution in Group 1 (n=37) and Group 2 (n=10) were 6-36 and 37-72 months. Meatal localization was glanular in 31, coronal in 7 and sub-coronal in 9 patients. Nine patients were secondary cases. The urethra proximal to the meatus was mobilized for a distance sufficient to allow it to reach the glans tip without tension. Then, the urethra was placed in the glanular bed and glanular reconstruction was performed. Operation duration, distance between the urethral meatus and the glans tip; and urethral mobilization length were measured and post-operative complications were noted.Results: Operation durations were similar in both groups. Three-fold urethral mobilization was sufficient for construction of tension-free urethra-glanular anastomosis. No fistula or retraction of the urethral meatus and chordee were observed. One patient required meatotomy. Conclusion: Distal hypospadias repair with the LUM technique is simple and effective. As no new urethral tube is constructed there is no risk of fistula. A slit-like urethral meatus with good functional results was obtained with the use of theLUM technique.
| Reference Key |
elemen2012limitedbalkan
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Elemen, Levent;Tugay, Melih; |
| Journal | balkan medical journal |
| Year | 2012 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.