Application of Thermal Labyrinth System to Reduce Heating and Cooling Energy Consumption
Clicks: 212
ID: 36219
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
60.3
/100
212 views
173 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #128 of 220 articles by views in energies
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 220 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
To reduce the energy consumption in buildings, modern buildings are increasingly becoming airtight. In these structures, the outdoor air is supplied inside through mechanical ventilation systems, which are essential for ensuring comfortable indoor air quality. However, these systems consume a considerable amount of energy in buildings. One potential solution is using a thermal labyrinth system, which is buried underneath the building. It can pre-cool or pre-heat the outdoor air through heat transfer with the surrounding soil. In this research, a number of case studies were conducted to optimize the thermal labyrinth design. The optimized thermal labyrinth system was derived using computational fluid dynamics (CFD) simulation. In addition, operation algorithms were developed for the efficient operation of the thermal labyrinth system in buildings. The results indicated that there were five operation modes, and the thermal labyrinth could be operated for seven months of the year. The energy reduction effects of the thermal labyrinth system were analyzed and were assessed by the transient system simulation (TRNSYS) tool. A 12% reduction in the annual heating and cooling energy was achieved by applying the thermal labyrinth system.
| Reference Key |
rim2018applicationenergies
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Rim, Minyeop;Sung, Uk-Joo;Kim, Taeyeon; |
| Journal | energies |
| Year | 2018 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.