Real-time compression feedback for patients with in-hospital cardiac arrest: a multi-center randomized controlled clinical trial.
Clicks: 342
ID: 35882
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
82.2
/100
342 views
241 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
StarRanked #1 of 2 articles by views in journal of intensive care
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
To determine if real-time compression feedback using a non-automated hand-held device improves patient outcomes from in-hospital cardiac arrest (IHCA).We conducted a prospective, randomized, controlled, parallel study (no crossover) of patients with IHCA in the mixed medical-surgical intensive care units (ICUs) of eight academic hospitals. Patients received either standard manual chest compressions or compressions performed with real-time feedback using the Cardio First Angel™ (CFA) device. The primary outcome was sustained return of spontaneous circulation (ROSC), and secondary outcomes were survival to ICU and hospital discharge.One thousand four hundred fifty-four subjects were randomized; 900 were included. Sustained ROSC was significantly improved in the CFA group (66.7% vs. 42.4%, < 0.001), as was survival to ICU discharge (59.8% vs. 33.6%) and survival to hospital discharge (54% vs. 28.4%, < 0.001). Outcomes were not affected by intra-group comparisons based on intubation status. ROSC, survival to ICU, and hospital discharge were noted to be improved in inter-group comparisons of non-intubated patients, but not intubated ones.Use of the CFA compression feedback device improved event survival and survival to ICU and hospital discharge.The study was registered with Clinicaltrials.gov (NCT02845011), registered retrospectively on July 21, 2016.
Abstract Quality Issue:
This abstract appears to be incomplete or contains metadata (105 words).
Try re-searching for a better abstract.
| Reference Key |
goharani2019realtimejournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Goharani, Reza;Vahedian-Azimi, Amir;Farzanegan, Behrooz;Bashar, Farshid R;Hajiesmaeili, Mohammadreza;Shojaei, Seyedpouzhia;Madani, Seyed J;Gohari-Moghaddam, Keivan;Hatamian, Sevak;Mosavinasab, Seyed M M;Khoshfetrat, Masoum;Khabiri Khatir, Mohammad A;Miller, Andrew C;, ; |
| Journal | journal of intensive care |
| Year | 2019 |
| DOI |
10.1186/s40560-019-0357-5
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.