Comparison Between Manual and (Semi-)Automated Analyses of Esophageal Diaphragm Electromyography During Endurance Cycling in Patients With COPD.

Clicks: 328
ID: 35791
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #26 of 73 articles by views in Frontiers in physiology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Electrocardiogram (ECG) contamination is present in diaphragm electromyography (EMGdi) recordings. Obtaining EMGdi without ECG contamination is crucial for EMG amplitude analysis. Manually selecting EMGdi in between QRS complexes has been most commonly applied in recent years (manual method). We developed a semi-automated analysis method based on Least Mean Square Adaptive Filtering combined with a synchronously recorded separate ECG channel to remove ECG artifacts from the EMGdi signals. We hypothesized that this approach would shorten analysis duration and might minimize the potential for inter-rater disagreement. We aimed to evaluate agreement between the semi-automated method and the manual method and inter-rater reliability of the manual method. Electromyography signals of seven patients with COPD were recorded using an esophageal catheter during an exercise test on a cycle ergometer. Four patients subsequently participated in an inspiratory muscle training (IMT) program for 8 weeks. After IMT, the tests were repeated. EMGdi/EMGdiMax as obtained either manually by the two assessors or retrieved from the semi-automated method were compared. Semi-automated EMGdi/EMGdiMax agreed well with values obtained by one of the two manual assessors (assessor 1) both at pre-intervention measurements (mean difference -0.5%, 95% CI: -19.6 to 18.6%) and for the pre/post IMT differences (mean difference 1.2%, 95% CI: -16.8 to 19.2%). Intra-class correlation coefficients between methods were 0.96 (95% CI: 0.94-0.97) at pre-intervention measurements and 0.78 (95% CI: 0.58-0.89) for pre/post IMT differences (both < 0.001). EMGdi/EMGdiMax from assessor 2 was systematically lower than from assessor 1 and agreed less well with the semi-automated method both at pre-intervention measurements (mean difference: 9.3%, 95% CI: -11.4 to 29.9%) and for pre/post IMT differences (mean difference 7.0%, 95% CI: -20.4 to 34.4%). Analysis duration of the semi-automated method was significantly shorter (29 ± 9 min) than the manual method (82 ± 20 min, < 0.001). The developed semi-automated method is more time efficient and will be less prone to inter-rater variability that was observed when applying the manual analysis method. It is, therefore, proposed as a new standard for objective EMGdi amplitude analyses in future studies.
Reference Key
dacha2019comparisonfrontiers Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Dacha, Sauwaluk;Janssens, Luc;Rodrigues, Antenor;Louvaris, Zafeiris;Janssens, Lotte;Gosselink, Rik;Langer, Daniel;
Journal Frontiers in physiology
Year 2019