Simultaneous determination of multiple components in rat plasma and pharmacokinetic studies at a pharmacodynamic dose of Xian-Ling-Gu-Bao capsule by UPLC-MS/MS.

Clicks: 294
ID: 34805
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #33 of 235 articles by views in Journal of pharmaceutical and biomedical analysis

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 235 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Xian-Ling-Gu-Bao capsule (XLGB) is an effective traditional Chinese medicine prescription (TCMP) that is used for the prevention and treatment of osteoporosis in China. A rapid, simple, efficient and stable method based on UPLC-MS/MS technology was developed for simultaneous determination of multiple components of XLGB in rat plasma. Mass spectrometric detection was performed in multiple reaction monitoring (MRM) mode with electrospray ionization (ESI). For twenty-one selected quantitative prototypes, all calibration curves showed favourable linearity (r>0.9932) in linear ranges. The lower limits of quantification (LLOQs) were 2 ng/mL for psoralen (PL), 2.5 ng/mL for asperosaponin VI (AS), 1 ng/mL for isopsoralen (IPS) and sweroside (SW), 0.5 ng/mL for magnoflorine (MA), bavachinin (BVN), tanshinone IIA (TA), timosaponin BII (TBII) and icaritin (ICT), 0.1 ng/mL for epimedin B (EB) and epimedin C (EC), 0.05 ng/mL for icariin (IC), isobavachalcone (IBC), psoralidin (PD), bavachin (BV), bavachalcone (BC), epimedin A (EA) and isobavachin (IBV), 0.02 ng/mL for neobavaisoflavone (NEO) and icariside I (ICI) and 0.01 ng/mL for icariside II (ICII). The intra-day and inter-day (low, medium, high) precision (relative standard deviation) for all analytes was less than 8.63%, and the accuracies (as relative error) were in the range of -12.45% to 8.91%. Extraction recoveries and matrix effects of analytes and IS were acceptable. All analytes were stable during the assay and storage in plasma samples. The validated method was successfully applied to the pharmacokinetics (PK) studies of the twenty-one prototypes at pharmacodynamic doses (0.3 and 1 g/kg/day). In addition, dynamic profiles of 28 metabolites (phase II conjugates: 23 glucuronide conjugates, 2 sulfate conjugates and 3 glucuronide or sulfate conjugates) were also monitored by their area/IS area-time curves. As a result, coumarins, prenylated flavonoids from Psoraleae Fructus, alkaloids and prenylated flavonol glycosides from Epimedii Herba, and iridoid glycosides, triterpenoid saponins from Dipsaci Asperoidis Radix were considered to be the key effective substances of XLGB due to their high exposure and appropriate pharmacokinetic features. This is the first report to reveal pharmacodynamic ingredients by a reversed pharmacodynamic (PD) - pharmacokinetics (PK) study.
Reference Key
tang2019simultaneousjournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Tang, Xi-Yang;Dai, Zi-Qin;Wu, Qing-Chang;Zeng, Jia-Xing;Gao, Meng-Xue;Xiao, Hui-Hui;Yao, Zhi-Hong;Dai, Yi;Yao, Xin-Sheng;
Journal Journal of pharmaceutical and biomedical analysis
Year 2019
DOI
S0731-7085(19)30783-6
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.