Quantification of Low Copy Number Protein in Single Cells.
Clicks: 193
ID: 34615
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
64.1
/100
193 views
158 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #73 of 194 articles by views in Analytical chemistry
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 194 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
We have developed an ultra-sensitive and highly selective method to quantify low copy number intracellular proteins in a single cell using low cost laser induced fluorescence (LIF) detector and BV605 fluorescent probe. Active caspase3 proteins in cells were labeled by corresponding antibody-BV605 fluorescent binding and a cell was injected into a 20 cm x 50 μm i.d. capillary column, followed by in-suit lyse and capillary electrophoresis (CE)-LIF analysis. About seven active caspase3 protein molecules in detection volume of 91 pL could be detected. In our method, cross-bounding proteins other than active caspase3 could be separated and distinguished by differences of retention time. By using Si photodiode assembly as fluorescent detector instead of PMT, the dynamic range of the LIF over 4 orders of magnitude. In this experiment, we found that the number of active caspase3 molecules in 98 single jurkat cells were from 629 to 12171, reflecting significant heterogeneity among the cells although they were from the same batch. For extended application, it could also be applied to quantify other types of low copy number proteins in a single cell as long as the corresponding antibodies are provided. This high-sensitive method could also be a promising tool for earlier cancer diagnosis and related disease pathway research which is relevant to low copy number proteins. In addition, this low-cost system could also be easily expanded to array system for high-throughput quantitation of low copy proteins in single cells.
| Reference Key |
shi2019quantificationanalytical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Shi, Meng;Geng, Xuhui;Wang, Chengye;Guan, Yafeng; |
| Journal | Analytical chemistry |
| Year | 2019 |
| DOI |
10.1021/acs.analchem.9b02989
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.