Determination of six benzotriazole ultraviolet filters in water and cosmetic samples by graphene sponge-based solid-phase extraction followed by high-performance liquid chromatography.
Clicks: 437
ID: 3449
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
81.5
/100
437 views
307 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #9 of 90 articles by views in Analytical and bioanalytical chemistry
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
An approach for fabrication of graphene sponge (GS)-based solid-phase extraction (SPE) followed by high-performance liquid chromatography (HPLC) with ultraviolet detection (HPLC-UV) is proposed, which was applied to determine the six benzotriazole UV filters in water and cosmetic samples. Several extraction conditions including type of elution solvent, the volume of elution solvent, and salt effect were optimized. Under the optimum conditions, the GS-SPE-HPLC-UV method shows a low limit of detection (LOD, S/N = 3) of 0.02-0.08 μg L for standard solution, limits of quantification (LOQ, S/N = 10) of 0.07-0.26 μg L for standard solution, wide linear ranges from 20.0 to 1000 μg L for all compounds for standard solution, correlation coefficients (r) of more than 0.999, except for 2-(2'-hydroxy-5'-methylphenyl)benzotriazole (UV-P), and acceptable reproducibility (relative standard deviations, RSDs < 6.5% for intra-day, RSDs < 8.1% for inter-day). The satisfactory recoveries were obtained in the range 89-105% with RSDs lower than 9.8% at the three spiked levels of 20, 50, and 100 μg L. Every home-made GS-SPE cartridge can be reused for more than 60 cycles. The method is facile, low-cost, rapid, sensitive, and suitable for the determination of UV filters in water and cosmetics samples. Graphical abstract ᅟ.
| Reference Key |
wang2018determinationanalytical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Wang, Xuemei;Wang, Juan;Du, Tongtong;Kou, Haixia;Du, Xinzhen;Lu, Xiaoquan; |
| Journal | Analytical and bioanalytical chemistry |
| Year | 2018 |
| DOI |
10.1007/s00216-018-1301-6
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.