Air coupled ultrasonic inspection with Lamb waves in plates showing mode conversion.
Clicks: 224
ID: 34235
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
66.9
/100
224 views
179 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #15 of 19 articles by views in ultrasonics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In this paper we demonstrate a non-destructive, non-contact detection method for small defects in thin polymer plates using an air coupled ultrasonic (ACUS) setup. There exist many applications for such methods, e.g. quality control in the manufacturing process or failure prevention by periodical inspections during the lifetime of a product. We demonstrate a setup for the inspection of plates together with signal analysis algorithms to process the measured data, meeting the challenges to handle the dispersive signals and establishing a robust failure criterion. Pressure waves from the transmitter excite different modes of Lamb waves inside the plate. These Lamb waves propagate in the plate and reradiate pressure waves into the air that are then detected by the receiver. Lamb mode conversion is used for defect detection. A numerical model allows the visualization of the propagating waves in the air as well as the Lamb waves inside the plate. Four key parameters of the setup are identified, two angles and two distances. The transmitter and the receiver angles are used to select which Lamb mode (anti-symmetric A or symmetric S) is mainly excited and detected, respectively. For the acquisition of the Lamb wave signal the distance from the transmitter to the receiver should be as large as possible but is limited by the attenuation of the signal. Measurements for different values of this distance are essential for signal analysis. The distance between transducer and plate surface should be as small as possible even if it may introduce secondary Lamb waves due to reflections of the pressure wave between transmitter and plate surface. Two algorithms, a model based one and a data driven one, are presented to separate Lamb modes that overlap in time. In these separated signals, the Lamb mode conversion from A to S is shown, allowing a localization of the defect. We conclude that defect detection and localization with Lamb mode conversion is possible with an air coupled ultrasonic setup. Multiple measurements along the propagation direction of the Lamb waves are necessary to allow a thorough signal analysis and visualize the mode conversion.
| Reference Key |
rommeler2019airultrasonics
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Römmeler, Arno;Zolliker, Peter;Neuenschwander, Jürg;van Gemmeren, Valentin;Weder, Mario;Dual, Jürg; |
| Journal | ultrasonics |
| Year | 2019 |
| DOI |
S0041-624X(19)30381-6
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.