Air coupled ultrasonic inspection with Lamb waves in plates showing mode conversion.

Clicks: 224
ID: 34235
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #15 of 19 articles by views in ultrasonics

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
In this paper we demonstrate a non-destructive, non-contact detection method for small defects in thin polymer plates using an air coupled ultrasonic (ACUS) setup. There exist many applications for such methods, e.g. quality control in the manufacturing process or failure prevention by periodical inspections during the lifetime of a product. We demonstrate a setup for the inspection of plates together with signal analysis algorithms to process the measured data, meeting the challenges to handle the dispersive signals and establishing a robust failure criterion. Pressure waves from the transmitter excite different modes of Lamb waves inside the plate. These Lamb waves propagate in the plate and reradiate pressure waves into the air that are then detected by the receiver. Lamb mode conversion is used for defect detection. A numerical model allows the visualization of the propagating waves in the air as well as the Lamb waves inside the plate. Four key parameters of the setup are identified, two angles and two distances. The transmitter and the receiver angles are used to select which Lamb mode (anti-symmetric A or symmetric S) is mainly excited and detected, respectively. For the acquisition of the Lamb wave signal the distance from the transmitter to the receiver should be as large as possible but is limited by the attenuation of the signal. Measurements for different values of this distance are essential for signal analysis. The distance between transducer and plate surface should be as small as possible even if it may introduce secondary Lamb waves due to reflections of the pressure wave between transmitter and plate surface. Two algorithms, a model based one and a data driven one, are presented to separate Lamb modes that overlap in time. In these separated signals, the Lamb mode conversion from A to S is shown, allowing a localization of the defect. We conclude that defect detection and localization with Lamb mode conversion is possible with an air coupled ultrasonic setup. Multiple measurements along the propagation direction of the Lamb waves are necessary to allow a thorough signal analysis and visualize the mode conversion.
Reference Key
rommeler2019airultrasonics Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Römmeler, Arno;Zolliker, Peter;Neuenschwander, Jürg;van Gemmeren, Valentin;Weder, Mario;Dual, Jürg;
Journal ultrasonics
Year 2019
DOI
S0041-624X(19)30381-6
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.