Diagnostic Performance of Biochemical Parameters to Diagnose Endogenous Hyperinsulinemic Hypoglycaemia

Clicks: 9
ID: 340677
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #131 of 138 articles by views in european journal of endocrinology

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 138 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
INTRODUCTION: The gold standard for diagnosing endogenous hyperinsulinemic hypoglycaemia (EHH) is the fasting test. The respective diagnostic value of insulin, C-peptide, proinsulin and beta-hydroxybutyrate levels in relation to glucose levels at the end of the fasting test remains ill-defined. We, therefore, aimed to explore the relevance of these parameters based on a literature review and individual data provided by different authors. METHODS: Extensive literature research was conducted in the databases Embase and Medline to identify case reports and original studies that report data on the fasting test e.g. fasting duration, blood glucose and insulin levels at the end of the fast, as well as C-peptide, proinsulin and beta-hydroxybutyrate levels, where available. Histology after surgery was defined as the diagnostic gold standard for patients with positive fasting tests. RESULTS: Data on fasting tests of 522 individual patients and 36 individual controls were identified. Sensitivity and specificity of the fasting test were 75.7% [95%CI 71.8-79.2] and 94.4% [95%CI 81.9-98.5], respectively, in our cohort. Whereas blood glucose, insulin and C-peptide are measured and reported in most cases, proinsulin and beta-hydroxybutyrate were reported in only 51% and 50%, respectively. In relation to blood glucose levels, C-peptide concentrations reached higher diagnostic accuracy (AUC 0.97) than insulin (AUC 0.93). Meanwhile, proinsulin and beta-hydroxybutyrate had an even higher diagnostic accuracy (both AUC = 0.99). CONCLUSIONS: In our dataset, combined glucose and C-peptide showed a strong discriminatory performance for EHH. However, proinsulin and beta-hydroxybutyrate show the highest diagnostic accuracy for diagnosing EHH yet are not measured on a regular basis.
Reference Key
openalex_W7236018296 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal european journal of endocrinology
Year 2026
DOI
10.1093/ejendo/lvag218
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.