Early Implementation of Guideline-Directed Medical Therapy and Outcomes in Cardiogenic Shock Supported by Micro-Axial Flow Pumps

Clicks: 16
ID: 340355
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #5 of 6 articles by views in european journal of heart failure

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
BACKGROUND: The role of guideline-directed medical therapy (GDMT) in patients with cardiogenic shock (CS) supported by mechanical circulatory support remains poorly defined. The feasibility and potential benefits of early GDMT initiation during Impella support are uncertain. METHODS: We analyzed a multicenter prospective registry of consecutive patients with CS treated with Impella between 2020 and 2024. GDMT exposure was defined as the number of heart failure therapies administered at device explantation. The primary outcome was in-hospital mortality. Multivariable logistic regression adjusted for clinical severity and early shock trajectory. Landmark analysis excluded patients dying within 5 days, while mixed-effects models accounted for center-level clustering. RESULTS: Among 140 patients (mean age 61 years; 20% female), 40% received concomitant ECMO (ECPella). In-hospital mortality was 38%. At explantation, 43% received at least one GDMT agent. Greater GDMT exposure was independently associated with lower mortality (OR 0.28 per additional therapy; 95% CI 0.14-0.58; p<0.001). This association remained consistent in landmark analysis (adjusted OR 0.31; 95% CI 0.16-0.66; p<0.001) and after excluding patients with cardiac arrest (adjusted OR 0.48; 95% CI 0.23-0.88; p=0.002). A graded relationship between GDMT intensity and survival was observed. Center-level variability was negligible (intraclass correlation coefficient 0.02). CONCLUSIONS: In patients with CS supported by Impella, early GDMT implementation was feasible in a substantial proportion of patients. Greater GDMT exposure at device explantation was associated with lower in-hospital mortality. Ventricular unloading may provide an opportunity to initiate outcome-modifying therapies during the acute phase of CS.
Reference Key
openalex_W7234867340 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal european journal of heart failure
Year 2026
DOI
10.1093/ejhf/xuag338
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.