Enhancing Cone-Beam Computed Tomography Image Quality Using Deep Learning-based Super-Resolution

Clicks: 18
ID: 339670
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #56 of 59 articles by views in dentomaxillofacial radiology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
OBJECTIVES: To develop deep learning super-resolution (SR) models for enhancing cone-beam computed tomography (CBCT). METHODS: Seventy CBCT volumes (75 µm voxel size) served as references. Paired low-resolution (LR) volumes (300 µm) were simulated using physics-based degradation. Four architectures were each trained with three loss configurations (L1; L1+edge; L1+edge+perceptual): Swin Transformer for Image Restoration (SwinIR), Hybrid Attention Transformer (HAT), Hybrid Multi-Axis Aggregation Network (HMA-Net), and Dense-Residual-Connected Transformer (DRCT). Performance was assessed with peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), learned perceptual image patch similarity (LPIPS), and deep image structure and texture similarity (DISTS). Three dentists ranked the 12 configurations in 28 sets using blinded forced-choice pairwise comparisons. Correlations of metrics and expert ranks were assessed using Spearman correlation. RESULTS: All configurations outperformed LR input and bicubic interpolation on every metric (p < 0.05). HMA-Net trained with L1+edge+perceptual loss performed best on LPIPS (0.216) and DISTS (0.186). HAT with L1 loss achieved the highest PSNR (28.79 dB) and SSIM (0.820). Experts ranked DRCT and HAT with L1 loss, and DRCT with L1+edge loss, as the best configurations (p < 0.001 versus others). Expert rank correlated moderately only with PSNR (rho = -0.65) and SSIM (rho = -0.60; both p < 0.05). CONCLUSIONS: Transformer-based SR improved the perceived quality of clinical CBCT images. HAT and DRCT trained with L1 pixel loss alone, and DRCT trained with L1 and edge loss, demonstrated superior performance. ADVANCES IN KNOWLEDGE: Transformer-based super-resolution improved expert-perceived detail of simulated low-resolution in vivo CBCT scans without additional radiation dose, supporting further validation on directly acquired low-resolution scans.
Reference Key
openalex_W7225984357 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal dentomaxillofacial radiology
Year 2026
DOI
10.1093/dmfr/twag075
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.