Simplified weak-beam dark-field STEM method for bend-contour-free dislocation loop observation using a commercial STEM system

Clicks: 3
ID: 339586
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #31 of 33 articles by views in Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
To advance the quantitative analysis of irradiation-induced defects, we successfully applied a simplified weak-beam dark-field scanning transmission electron microscopy (WBDF-STEM) technique using a standard spherical-aberration-corrected STEM setup, requiring no specialized hardware modifications. By systematically optimizing the illumination geometry with a 10 μm condenser aperture and the imaging geometry with camera lengths of 100 cm and 40 cm, we effectively suppressed macro-scale bend contours and micro-scale surface oxide moiré artifacts. This optimization relies on the combined effect of the probe convergence semi-angle and the acceptance semi-angle to integrate and average out localized intensity fluctuations, while objective-aperture selection at the 2g position reduces oxide-derived moiré contrast. These improvements provide a more uniform background, enabling the reliable identification of the Burgers vectors of nanometer-scale dislocation loops (b = a < 100> and b = a/2<111>) through direct correlation of contrast behaviors across distinct g vectors. Consequently, this methodology provides a practical and readily implementable approach for diffraction-contrast-based analysis of radiation-induced microstructures using a commercial AC-STEM instrument.
Reference Key
openalex_W7225798469 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada
Year 2026
DOI
10.1093/jmicro/dfag039
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.