Alfred Kocher technique for prevention of patient–prosthesis mismatch in paediatric patients

Clicks: 1
ID: 339578
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #56 of 57 articles by views in Multimedia Manual of Cardio-Thoracic Surgery

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Aortic valve replacement requires special considerations in paediatric patients, who are not yet fully grown. The Ross procedure remains the gold standard in paediatric patients as it offers growth potential. If the Ross procedure is not feasible, or the size of the aortic annulus precludes placement of an adult-sized mechanical prosthesis, the problem of patient-prosthesis mismatch and subsequent aortic valve reinterventions arises. The standardized option for this patient cohort is the Konno incision and patch ventriculoplasty in combination with an adult-sized mechanical prosthesis, which carries substantial procedural complexity and risk. This video tutorial demonstrates posterior aortic root enlargement using the Alfred Kocher technique in a 7-year-old female with a functionally unicuspid aortic valve and a bicuspid pulmonary valve. The bicuspid pulmonary valve was an unplanned intraoperative finding, making the patient ineligible for a durable autograft transplantation. The technique involves an inverted T-shaped incision in the centre of the non-coronary sinus, and reconstruction with a barrel-shaped patch tailored from a 28 mm Valsalva prosthesis to augment the non-coronary sinus in an anatomical fashion, allowing upsizing by 5 mm in annular diameter. This technique enabled implantation of a 21 mm size mechanical prosthesis (diameter = 24 mm) upsized from a 19 mm annulus.
Reference Key
openalex_W7225820363 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Multimedia Manual of Cardio-Thoracic Surgery
Year 2026
DOI
10.1510/mmcts.2026.106
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.