Seeing the Gaps: Heatmaps, Metrics, and the Hidden Failures of Explainable AI in Dentomaxillofacial Radiology – A Systematic Review

Clicks: 14
ID: 339196
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #58 of 59 articles by views in dentomaxillofacial radiology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Objectives This systematic review aims to evaluate the techniques and reported patterns of heatmap-based visual explanations in deep learning (DL) systems for dental radiographic classification tasks. Methods A literature search following PRISMA guidelines was conducted in PubMed, Scopus, IEEE Xplore Library, Oria.no and Google Scholar to retrieve studies using DL for dental classification tasks. Only articles with a visual explanation (heatmap) were selected. Risk of bias assessment was done with QUADAS-2, PROBAST-AI and CEBM. The heatmap technique, reasons for inclusion, explanations provided and patterns were analysed. Results In the 136 studies reviewed, Grad-CAM was the most commonly used technique. The predominant reason for using visual explanations was to understand the decision-making process of the DL model. Some heatmaps reflect established radiographic criteria, while others exhibit unique, label-dependent patterns that sometimes emphasise irrelevant areas. Cropping to the region of interest influences visual explanations. Conclusions Visual explanations seem clinically plausible to domain experts when aligned with domain knowledge, but clinical plausibility does not equal technical faithfulness. Formal faithfulness testing was rarely performed among the included studies. Therefore, explanations should not be assumed to accurately represent the model’s underlying reasoning. Limitations include the evaluation of studies not primarily designed for visual explanation assessment. No funding was received for this review. Authors declare no competing interests. Advances in knowledge Visual explanations, while clinically plausible when aligned with domain knowledge, remain insufficiently validated and should not be assumed to faithfully represent model reasoning. An implausible explanation does not necessarily indicate model failure. Domain/task-specific evaluation metrics for explainable AI in dentomaxillofacial radiology are needed.
Reference Key
openalex_W7225454354 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal dentomaxillofacial radiology
Year 2026
DOI
10.1093/dmfr/twag074
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.