Successful atrial leadless pacemaker implantation in an 11-year-old with congenital sinus node dysfunction: A Case Report

Clicks: 5
ID: 338058
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #401 of 408 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 408 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Sinus node dysfunction (SND) is rare in the paediatric population. Leadless atrial pacing represents a novel therapeutic option. To our knowledge, this case represents the youngest reported patient to receive an atrial leadless pacemaker (AVEIR AR). While ventricular leadless pacing has been described in children, atrial leadless pacing experience in this population remains extremely limited. Case Summary An 11-year-old boy with lifelong bradycardia documented since fetal life presented with exertional dyspnoea and recurrent syncopal episodes. Electrocardiography revealed nodal rhythm without sinus activity. Electrophysiological evaluation demonstrated a corrected sinus node recovery time (cSNRT) of 4800 ms and absence of chronotropic response to intravenous atropine (0.04 mg/kg IV). The patient met Class I criteria for permanent pacemaker implantation according to current paediatric pacing consensus recommendations, given symptomatic sinus node dysfunction with chronotropic incompetence. An AVEIR AR leadless pacemaker was successfully implanted at the base of the right atrial appendage with optimal electrical parameters. No procedural or 18-month follow-up complications were observed. Discussion This case demonstrates procedural feasibility of atrial leadless pacing in a carefully selected paediatric patient, with encouraging mid-term follow-up. Larger studies are required to establish long-term safety and clinical outcomes.
Reference Key
openalex_W7224877552 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag805
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.