Pigtail catheter entrapment during post-dilation causing Sapien-3 Ultra RESILIA valve damage with severe intravalvular aortic regurgitation: a case report

Clicks: 6
ID: 338045
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #395 of 408 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 408 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Acute prosthetic leaflet dysfunction after transcatheter aortic valve implantation (TAVI) is rare but potentially life-threatening. Catheter-induced leaflet trauma during post-dilatation is less well recognised. Case summary An 88-year-old woman with severe symptomatic aortic stenosis and high-risk aortic root anatomy—including a narrow sinus of Valsalva, low left coronary artery (LCA) height, and a small, calcified sinotubular junction—underwent elective TAVI with a 23-mm Sapien 3 Ultra RESILIA valve deployed with a 2-mL underfill under prophylactic LCA protection. Initial transthoracic echocardiography and aortography showed trivial paravalvular leak and preserved LCA flow. During post-dilatation, the distal balloon tip and Safari guidewire snagged the pigtail catheter, pulling it across the prosthesis and into the left ventricle. Unrecognised in a crowded fluoroscopic field, the catheter became trapped between the expanding balloon and the valve frame, causing focal leaflet injury and severe intravalvular aortic regurgitation with haemodynamic collapse. Emergent valve-in-valve implantation with a 20-mm Sapien 3 Ultra RESILIA under bilateral coronary protection resolved the regurgitation, but displaced leaflet tissue caused LCA ostial compromise requiring chimney stenting. The patient recovered uneventfully and remained stable at 30-day follow-up. Discussion This case illustrates pigtail catheter entrapment during post-dilatation as a preventable cause of acute prosthetic leaflet damage and severe intravalvular regurgitation. It underscores the need for meticulous catheter management, critical reassessment of post-dilatation in older patients with trivial leak, and individualised valve platform and size selection in small, anatomically constrained aortic roots.
Reference Key
openalex_W7224839352 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag818
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.