Persistent peri-device leak following left atrial appendage occlusion treated with hybrid coil- and plug-based closure: a case report

Clicks: 3
ID: 337990
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #403 of 408 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 408 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Left atrial appendage occlusion (LAAO) is an emerging alternative to long-term anticoagulation in patients with atrial fibrillation, but peri-device leaks remain a clinical challenge. Case summary A 63-year-old man with permanent atrial fibrillation, heart failure, a prior ischemic stroke history was referred for LAAO due to recurrent anticoagulation-related bleeding. Pre-procedural computer tomography (CT) showed a markedly enlarged appendage suitable for a 35 mm WATCHMAN FLX®, which was implanted under intracardiac echocardiography guidance, with subsequent transition to aspirin. Three months later, CT revealed a tilted device with a peri-skirt leak; an ischemic stroke had occurred in the interim, and anticoagulation was resumed. An Amplatzer Vascular Plug II was implanted but follow-up CT demonstrated persistent contrast passage and more but incomplete occlusion. Three months later, the patient experienced a second stroke, and CT confirmed ongoing peri-device flow. A hybrid leak-closure procedure was performed with coils in the appendage and within the device, followed by a 12 mm plug at the leak channel, achieving near-complete occlusion. At 7-month follow-up, the patient remained on rivaroxaban therapy, briefly interrupted due to haematuria associated with nephrolithiasis. Discussion Most cases of peri-device leak after LAAO are related to suboptimal device alignment, incomplete endothelialization, or persistent peri-skirt channels. In our case, device tilt with a peri-skirt tract persisted despite initial plug-based closure. This case provides insight into the potential role of hybrid coil- and plug-based strategies in enhancing occlusion but also highlights that anticoagulation remains necessary when full occlusion is not obtained.
Reference Key
openalex_W7225010376 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag817
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.