Experimental and numerical studies of two arterial wall delamination modes.
Clicks: 121
ID: 33773
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
76.5
/100
121 views
99 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #39 of 41 articles by views in Journal of the mechanical behavior of biomedical materials
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Arterial wall dissection, which results from various pathophysiological processes, can lead to the occurrence of large area delamination in the aortic wall that can potentially block blood flow and lead to deleterious clinical conditions. Despite its critical clinical relevance, few studies have focused on investigating the failure mode of delamination in the arterial wall. In this study, we quantify the energy release rate of the medial layer of a porcine abdominal aorta via two delamination experiments: the mixed-mode delamination experiment and the "T"-shaped delamination experiment. A cohesive zone model (CZM) is applied to simulate the arterial wall delamination and Holzapfel-Gasser-Ogden (HGO) material model is used to capture the bulk arterial material behavior. A set of parameter values for the HGO and CZM models are identified through matching simulation predictions of the load vs. load-point displacement curve with experimental measurements. Then the parameter values and critical energy release rates obtained from experiments are used as input data for simulation predictions for two arterial wall delamination experiments. The simulation predictions show that the delamination front matches well with experimental measurements. Moreover, the mixed-mode delamination experiment reveals a shear mode-dominated failure event, whereas the "T"-shaped delamination experiment is an opening failure process. The integration of experimental data and numerical predictions of arterial delamination events provides a comprehensive description of distinct failure modes and aids in the prediction of aortic dissection.
| Reference Key |
leng2018experimentaljournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Leng, Xiaochang;Zhou, Boran;Deng, Xiaomin;Davis, Lindsey;Lessner, Susan M;Sutton, Michael A;Shazly, Tarek; |
| Journal | Journal of the mechanical behavior of biomedical materials |
| Year | 2018 |
| DOI |
S1751-6161(17)30418-6
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.