Full Characterisation of the Polarimetric Primary Beams of the GRAO 32-m Telescope

Clicks: 6
ID: 337363
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #49 of 51 articles by views in RAS Techniques and Instruments

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Direction-dependent instrumental polarisation is a major systematic limitation in high-fidelity single-dish radio polarimetry, yet a unified characterisation of beam leakage and the conditioning of polarisation recovery is lacking for the Ghana Radio Astronomy Observatory (GRAO) 32-m telescope. We aim to establish a quantitative, direction-dependent polarimetric beam model at 5.0 and 6.7 GHz. High-resolution GRASP electromagnetic simulations of the nominal telescope configuration are used to derive the full complex Jones response and corresponding Mueller matrices, from which beam shape, beam squint, instrumental Stokes leakage, and intrinsic cross-polarisation ratio (IXR) are evaluated across the primary beam. The Stokes I beams have half-power beam widths of 396.4 and 295.3 arcsec at 5.0 and 6.7 GHz, respectively, with main-beam efficiencies of 56.4 and 55.6 per cent. At 5.0 GHz, the circular-polarisation beam squint is 9.96 arcsec (2.5 per cent of the HPBW), whereas no statistically significant squint is detected at 6.7 GHz. Leakage from Stokes I into linear polarisation remains below 0.1 per cent within the half-power beam but increases substantially towards the sidelobes. IXR reaches approximately 80 dB on axis and decreases with angular offset. These results establish the intrinsic electromagnetic polarimetric response of the GRAO 32-m telescope and provide a quantitative baseline for direction-dependent calibration and subsequent observational validation.
Reference Key
openalex_W7223866515 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal RAS Techniques and Instruments
Year 2026
DOI
10.1093/rasti/rzag087
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.