UTILITY OF INDOCYANINE GREEN FLUORESCENCE IMAGING IN BURN MANAGEMENT: A SYSTEMATIC REVIEW

Clicks: 13
ID: 333599
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #89 of 93 articles by views in journal of burn care & research : official publication of the american burn association

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
ABSTRACT The implementation of near-infrared fluorescence (NIRF) imaging using indocyanine green (ICG) has seen a rising implementation in burn care in recent years, with expanding clinical indications and increasing evidence supporting its use. A systematic review was carried out following PRISMA guidelines, employing PubMed, Web of Science, CINAHL, and EMBASE databases to locate studies on the perioperative use of ICG in burn patients. Two independent reviewers assessed all articles for eligibility based on predefined inclusion criteria. Extracted data included study characteristics, patient demographics, clinical indications, ICG dosing regimens, administration timing, and reported perioperative outcomes. A total of 12 studies enrolling 204 burn patients, published between 1995 and 2025, were included for qualitative synthesis. Of these, 7 (58.3%) were prospective, single-center experimental studies; 3 (25%) were prospective, multicenter, blinded trials; 1 (8.3%) was a retrospective study; and 1 (8.3%) was a case series. The primary clinical uses of ICG in burn management included: assessment of burn depth reported in 6 studies, intraoperative delineation of necrotic tissue requiring excision in 3 studies, utility of ICG in liver function measurement in 2 studies and another research analyzed the estimation of plasma volume in burn patients. ICG fluorescence imaging is a promising adjunctive tool for burn assessment, particularly in identifying non-perfused tissue. It enhances the ability to accurately assess burn depth and helps to determine surgical margins during burn excision. Furthermore, ICG pharmacokinetics may provide insight into liver involvement and prognostic outlook in severe burn cases. However, its current role remains complementary to clinical evaluation. Further standardized and high-quality studies are required to define its diagnostic accuracy and clinical impact.
Reference Key
openalex_W7223345383 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal journal of burn care & research : official publication of the american burn association
Year 2026
DOI
10.1093/jbcr/irag176
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.