Conservative Management of a Dislodged Leadless Pacemaker Wedged in the Pulmonary Artery Assessed by Pulmonary Perfusion Scintigraphy: A Case Report

Clicks: 10
ID: 332652
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #349 of 408 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 408 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Leadless pacemakers reduce complications associated with conventional transvenous systems; however, device dislodgement with pulmonary artery embolization is a rare complication unique to leadless pacemakers. Although prompt retrieval is generally recommended, retrieval from the pulmonary artery may carry procedural risks, particularly in elderly or high-risk patients. Case Summary An 84-year-old woman with complete atrioventricular block underwent implantation of a leadless pacemaker. Although the pacing threshold was favorable, the R-wave amplitude was low, and unstable device movement was observed after tether release, suggesting inadequate fixation. Two hours after implantation, pacing failure occurred, and chest radiography showed migration of the device into the right pulmonary artery. The following day, the device migrated to the left posterior basal segmental pulmonary artery and remained stably wedged. Because of the risk associated with retrieval, conservative management was selected, and a transvenous pacemaker was implanted. Serial lung perfusion scintigraphy demonstrated right-to-left perfusion distributions of 60.5% versus 39.5% at 10 days, 59.1% versus 40.9% at 3 months, and 58.5% versus 41.5% at 1 year, without progressive deterioration in left lung volume. The patient remained asymptomatic over 3 years of follow-up. Discussion This case illustrates that conservative management may be feasible in carefully selected high-risk patients when an embolized leadless pacemaker is stably wedged within the pulmonary artery. Serial pulmonary perfusion scintigraphy may provide objective evidence of preserved pulmonary perfusion and support long-term follow-up after conservative management.
Reference Key
openalex_W7222816416 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag749
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.