Right internal jugular approach for transcatheter edge-to-edge mitral valve repair using the MitraClip G4 system after failed transfemoral access: a case report

Clicks: 10
ID: 332593
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #348 of 408 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 408 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Transcatheter edge-to-edge repair of the mitral valve is conventionally performed via transfemoral venous access. When this route is not feasible, the right internal jugular vein may provide an alternative, but procedural experience remains limited. Case Summary A 93-year-old woman with refractory heart failure had atrial functional mitral regurgitation and low-flow, low-gradient aortic stenosis. After transcatheter aortic valve implantation, moderate-to-severe mitral regurgitation persisted. Transfemoral edge-to-edge repair was unsuccessful because severe iliac venous tortuosity prevented adequate catheter control. The procedure was subsequently performed via the right internal jugular vein using the MitraClip G4 system. A pre-existing iatrogenic atrial septal defect was reused, and temporary left ventricular apical wire support facilitated advancement of the steerable guiding catheter into the left atrium. Stepwise + knob rotation increased height and working space, improved the markedly under-straddled configuration, and permitted further advancement of the clip delivery system. Subsequent M- and P-knob adjustments achieved an appropriate trajectory towards A2/P2, with an S-shaped fluoroscopic configuration. Leaflet grasping reduced mitral regurgitation to mild without access-site complications. Mild mitral regurgitation was maintained at 6 months without heart-failure rehospitalization. Discussion Right internal jugular access may be a feasible alternative when transfemoral access is not possible. Successful navigation requires recognition of access-specific catheter behaviour and adaptation of steering under real-time fluoroscopy and transoesophageal echocardiography. An S-shaped fluoroscopic configuration may serve as a practical landmark of a favourable trajectory towards the mitral valve.
Reference Key
openalex_W7222594025 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag756
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.