Long IVUS-Attenuated Plaque Without No-Reflow: Histological Findings of Captured Embolic Debris and Implications for the Interpretation of IVUS Attenuation: A Case Report

Clicks: 9
ID: 331819
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #361 of 408 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 408 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background The no-reflow phenomenon during percutaneous coronary intervention (PCI) is commonly associated with distal embolization from high-risk coronary plaques, including lesions with intravascular ultrasound (IVUS)-defined attenuation. Histopathological analysis of embolic debris captured during PCI is rarely reported and may provide additional insights into the relationship between plaque characteristics and coronary flow outcomes. Case Summary An 84-year-old man presented with acute coronary syndrome and decompensated heart failure. Coronary angiography demonstrated severe multivessel coronary artery disease, including a long right coronary artery lesion with extensive IVUS attenuation. Given the high risk of distal embolization, PCI was performed using a distal protection device. Drug-eluting stents were successfully implanted, and TIMI flow grade 3 was maintained throughout the procedure without slow-flow or no-reflow. Histopathological examination of debris captured by the distal protection device demonstrated predominantly fibrin- and collagen-rich thrombotic material with macrophage infiltration and no apparent abundant lipid component. The patient experienced an uneventful recovery and was discharged without procedural complications. Conclusion The composition of retrieved embolic debris captured during PCI differed from the expected imaging phenotype. This case highlights the potential discrepancy between intracoronary imaging appearance and embolized material and underscores the multifactorial nature of coronary slow-flow and no-reflow. Careful interpretation of IVUS attenuation and embolic pathology is warranted when assessing procedural risk.
Reference Key
openalex_W7220929096 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag739
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.