Inter-Device Agreement Between Vectra H2 and LifeViz Mini for Nasolabial Volumetric Assessment After Thread Lifting: A Post Hoc Method-Comparison Study

Clicks: 8
ID: 331749
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #112 of 125 articles by views in Aesthetic Surgery Journal Open Forum

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 125 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Objective quantification of subtle facial volume change requires reliable three-dimensional (3D) imaging, but measurements from different systems may not be equivalent. Objectives To evaluate agreement between Vectra H2 and LifeViz Mini for nasolabial volumetric assessment after thread lifting. Methods This post hoc secondary retrospective method-comparison study analyzed paired images prospectively acquired in a parent study. Fifteen women treated with absorbable polydioxanone mesh threads contributed 74 paired side-specific measurements across 43 participant visits. A standardized 1 cm2 nasolabial region of interest was analyzed with Vectra H2 (Canfield Scientific, Inc., Parsippany, NJ) and LifeViz Mini (QuantifiCare S.A., Valbonne, France). Agreement was assessed using an absolute-agreement intraclass correlation coefficient (ICC), Bland-Altman analysis, and paired testing. A participant-level sensitivity analysis averaged bilateral measurements within visits and then averaged visits within each participant. Results Mean age was 41.87 ± 7.85 years (range, 34-56 years). The paired measurements did not differ significantly (exact two-sided Wilcoxon P=.356); the median LifeViz Mini-minus-Vectra H2 difference was 0.00108 cm3. The ICC was 0.977 (95% CI, 0.963-0.985). Mean bias was 0.00045 cm3, with limits of agreement from -0.00924 to 0.01013 cm3. Participant-level findings were consistent (P=.804; ICC=0.953; mean bias, 0.00019 cm3). Conclusions Vectra H2 and LifeViz Mini produced highly concordant nasolabial volume-change measurements under standardized conditions. The participant-level sensitivity analysis supported the robustness of the findings, although larger prospective studies are required.
Reference Key
openalex_W7220860420 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Aesthetic Surgery Journal Open Forum
Year 2026
DOI
10.1093/asjof/ojag195
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.