FP7.5 Impact of Computer-Assisted Intraoperative Imaging on Correction Accuracy and 1-Year Outcomes After Periacetabular Osteotomy

Clicks: 10
ID: 331319
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #321 of 444 articles by views in Journal of hip preservation surgery

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 444 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract ICLB07 - The Digital Surgeon: Practical Tools and Navigation Basics for Your Everyday Practice, Session Room 12 (BMCC Level 3), October 8, 2026, 14:00 - 16:00 Background The optimal acetabular positioning during periacetabular osteotomy (PAO) remains up for debate, and intraoperative assessment of correction has traditionally relied on surgeon judgment and visual assessment. Intraoperative computer-assisted imaging systems, such as Radlink, provide immediate feedback on fragment positioning. This study aimed to (1) evaluate whether the use of Radlink reduces variability in postoperative radiographic measurements, and (2) determine its impact on achieving clinically meaningful patient-reported outcome measures (PROMs) following PAO. Methods This retrospective review included 262 patients (92% female; mean age, 25.1 ± 8.0 years) who underwent PAO between 2018 and 2022 with minimum 1 year follow-up. Patients undergoing revision PAO or staged bilateral PAO with mixed Radlink use were excluded. Patients were grouped based on the use of intraoperative imaging: Radlink (n=147) versus no Radlink (n=115). PROMs, demographic, and radiographic data were collected. Radiographic parameters included lateral center-edge angle (LCEA) and anterior wall index (AWI), with predefined target ranges. The recently defined minimal clinically important difference (MCID) and patient acceptable symptom state (PASS) thresholds for PAO were used to assess patient outcomes. Results A greater proportion of Radlink patients achieved the target postoperative lateral center-edge angle (LCEA, 30–38°) compared with non-Radlink patients (83% vs 70%, p=0.01). A similar, non-significant difference was observed for anterior wall index (AWI, 0.30-0.51°) (50% vs 43%, p=0.21). Radlink patients demonstrated higher 1-year PROMs; the difference approached statistical significance for modified Harris Hip Score (88.9 ± 12.0 vs 84.1 ± 14.4, p=0.05) but not for International Hip Outcome Tool-12 (79.3 ± 20.1 vs 74.9 ± 22.9, p=0.43). A greater proportion of Radlink patients achieved an MCID or PASS threshold (93% vs 89%) at 1 year, without reaching statistical significance. Conclusion The use of computer-assisted intraoperative imaging software was associated with improved accuracy in achieving target acetabular correction, particularly for LCEA. While radiographic precision improved, this did not translate into significant differences in short-term PROMs. For an experienced surgeon, this software may not lead to drastic differences in outcomes, but appears to enhance correction accuracy and precision, which could be especially beneficial for less experienced surgeons during the learning curve.
Reference Key
openalex_W7220438217 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Journal of hip preservation surgery
Year 2026
DOI
10.1093/jhps/hnag043.053
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.