EP1.97 Functional and Gait Outcomes Following Periacetabular Osteotomy and Structured Postoperative Rehabilitation

Clicks: 14
ID: 331251
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #222 of 444 articles by views in Journal of hip preservation surgery

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 444 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Introduction Hip dysplasia (HD) is characterized by insufficient acetabular coverage, leading to increased joint stress, labral and chondral injury, and functional impairment. Bernese periacetabular osteotomy (PAO) restores acetabular coverage and improves load distribution across the hip joint. Methods This single-case analysis evaluated spatiotemporal gait parameters, quality of life, and function in a 37-year-old female with symptomatic hip dysplasia (LCEA 6°, Tönnis angle 18°, extrusion index 44%, VAS = 8) preoperatively and at 4 months following PAO and structured postoperative rehabilitation. Radiographic parameters were consistent with acetabular undercoverage and hip instability. Gait analysis was performed using a Vicon® motion capture system, with 3D reconstruction via Motion Monitor (Innovative Sports Training®, Inc.). Patient-reported outcomes included HAGOS and iHOT-33. Results At 4 months postoperatively, gait analysis demonstrated a slower yet more symmetric pattern. Walking speed decreased by 20% (1.32 to 1.05 m/s), accompanied by reduced cadence (143.0 to 118.5 steps/min, −17.1%) and increased bilateral cycle and step times. Despite reduced performance, inter-limb symmetry improved substantially. Step length absolute asymmetry decreased from 0.055 to 0.001, and step time asymmetry from 0.041 to 0.001, indicating near-normalization of step mechanics. In contrast, cycle time asymmetry increased from 0.002 to 0.045, suggesting a residual temporal discrepancy in the operated limb. Radiographic correction was achieved, with LCEA improving from 6° to 34°, Tönnis angle from 18° to 8°, and extrusion index from 44% to 12.5%. Postoperative values fall within ranges reported as adequate for acetabular coverage restoration. The achieved LCEA may suggest slight overcorrection, although still within acceptable ranges. Patient-reported outcomes improved markedly, with iHOT-33 increasing from 20% to 33.5%, and HAGOS subscales improving, particularly in sport/recreation (+252%), quality of life (+133%), pain (+106%), and activities of daily living (+100%), although physical activity decreased by 20%. Conclusion At 4 months after PAO, gait performance remains reduced, reflecting early postoperative adaptation. However, improvements in inter-limb symmetry and patient-reported outcomes indicate functional recovery and improved load distribution. Structural correction appears to precede full restoration of gait performance, reinforcing the importance of comprehensive rehabilitation following surgery.
Reference Key
openalex_W7220424733 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Journal of hip preservation surgery
Year 2026
DOI
10.1093/jhps/hnag043.281
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.