Assessment of the Impact of Oil-Contaminated Sand on the Structural Performance of Reinforced Concrete: Experimental and Numerical Analysis

Clicks: 11
ID: 329968
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #1 of 5 articles by views in Mesopotamian journal of civil engineering.

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This study presents a systematic investigation of the physical, chemical, microstructural, and mechanical properties of oil-contaminated sand (OCS) and the resulting concrete, alongside a structural evaluation of RC beams under monotonic loading. Sixteen groups of concrete cylinders were cast at oil contamination levels of 0–30% by weight of fine aggregate, and six RC beams were fabricated and tested at contamination levels of 0%, 4%, 8%, 12%, 16%, and 20%. Physical testing showed OCS has an increase of 249% water absorption and a decrease in specific gravity of 7.3% compared to clean sand. At 2% oil content, there was a slight improvement in all mechanical properties of concrete, but as the content increased, the concrete properties gradually and nonlinearly decreased; at 30% oil content, the concrete compressive strength, splitting tensile strength, modulus of rupture and modulus of elasticity, were reduced by 70.91%, 89.94%, 71.43%, and 44.84%, respectively. From a structural point of view, a 70% decrease in cracking load, 61.1% decrease in ultimate load and 60% decrease in the deflection capacity at midspan were observed with contamination increasing from 0% to 20%, and a fundamental transition in failure mode from ductile flexural to explosive brittle failure. The practical limit for structural applications is determined as 8-12% contamination.
Reference Key
openalex_W7214540464 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Mesopotamian journal of civil engineering.
Year 2026
DOI
10.58496/mjce/2026/006
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.