Support Vector Machine Regression for Calibration Transfer between Electronic Noses Dedicated to Air Pollution Monitoring
Clicks: 256
ID: 32965
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
65.3
/100
256 views
180 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #890 of 1,694 articles by views in sensors
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Recently, the emergence of low-cost sensors have allowed electronic noses to be considered for densifying the actual air pollution monitoring networks in urban areas. Electronic noses are affected by changes in environmental conditions and sensor drifts over time. Therefore, they need to be calibrated periodically and also individually because the characteristics of identical sensors are slightly different. For these reasons, the calibration process has become very expensive and time consuming. To cope with these drawbacks, calibration transfer between systems constitutes a satisfactory alternative. Among them, direct standardization shows good efficiency for calibration transfer. In this paper, we propose to improve this method by using kernel SPXY (sample set partitioning based on joint x-y distances) for data selection and support vector machine regression to match between electronic noses. The calibration transfer approach introduced in this paper was tested using two identical electronic noses dedicated to monitoring nitrogen dioxide. Experimental results show that our method gave the highest efficiency compared to classical direct standardization.
| Reference Key |
laref2018supportsensors
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Laref, Rachid;Losson, Etienne;Sava, Alexandre;Siadat, Maryam; |
| Journal | sensors |
| Year | 2018 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.