Disappearance of Local Ventricular Components during Extrastimulus Pacing after Ultra-low-temperature Cryoablation for Ventricular Tachycardia: A Case Report

Clicks: 10
ID: 329557
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #343 of 408 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 408 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Ultra-low-temperature cryoablation (ULTC) enables the creation of deep and potentially transmural myocardial lesions and is increasingly used for ventricular tachycardia (VT) substrate modification. However, the chronic electrophysiological properties of myocardium following extreme cryothermal injury remain incompletely understood. Case summary A 66-year-old man with dilated cardiomyopathy and a cardiac resynchronization therapy defibrillator presented with recurrent sustained VT 15 months after ULTC of the left ventricular outflow tract. During repeat ablation, high-density mapping revealed sharp local ventricular electrograms within the prior ablation region. Programmed ventricular stimulation from the right ventricular outflow tract reproducibly induced disappearance of these sharp local components during extrastimulus pacing, while the surface QRS complex remained preserved, indicating preserved global ventricular activation. The phenomenon was consistently observed across different pacing protocols. Radiofrequency ablation targeting this region resulted in elimination of the sharp local electrograms, whereas dull far-field signals persisted. After ablation, VT was no longer inducible, and the patient remained free from recurrence at 3-month follow-up. Discussion This case demonstrates a reproducible disappearance of near-field ventricular electrograms during extrastimulus pacing in myocardium previously treated with ULTC. The findings suggest localized refractoriness or source–sink mismatch within partially injured myocardium, rather than conventional slow conduction. These observations provide novel insight into the chronic electrophysiological effects that may occur after ULTC and may have implications for substrate assessment during repeat VT ablation.
Reference Key
openalex_W7214072850 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag721
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.