Evaluation of an Upper Arm Capillary Blood Collection Device Compared with Venous and Fingerstick Sampling
Clicks: 1
ID: 329490
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #11 of 11 articles by views in the journal of applied laboratory medicine
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
BACKGROUND: Upper arm capillary blood collection devices may expand access to laboratory testing outside traditional phlebotomy settings. We evaluated the analytical performance and patient preference of the ImPress, an investigational-use upper arm capillary blood collection device compared with venous and fingerstick sampling. METHODS: Matched samples were collected from 43 healthy volunteers. Sixteen routine chemistry and lipid analytes were measured on standard laboratory platforms. Agreement was assessed using Deming regression and bias at medical decision points (MDPs), with acceptability defined by total allowable error (TEa). Hemolysis indices were compared across collection methods. Participants completed a survey. RESULTS: A total of 315 specimens were analyzed. Thirteen of 16 analytes met predefined acceptance criteria for upper arm capillary compared with venous sampling. Mean bias at MDP ranged from -3.1% to 10% for venous vs upper arm capillary samples. Albumin, calcium, and aspartate aminotransferase (AST) did not meet acceptance criteria, primarily because all samples were within a tight normal range. All correlation coefficients (R, Deming regression) were ≥0.90, indicating linear relationships between collection modalities. Hemolysis indices for samples collected by the upper arm capillary device were well below assay interference thresholds. Mean pain scores (0 to 10 scale) were lowest for upper arm capillary (0.55) compared with venipuncture (2.61) and fingerstick (2.87). Most participants (74%) reported a preference for an upper arm capillary device. CONCLUSIONS: Upper arm capillary blood collection demonstrated strong analytical agreement with venous and fingerstick sampling for most routine analytes, low clinically significant hemolysis, and high patient acceptability. These findings support its potential use in decentralized and remote laboratory testing.
| Reference Key |
openalex_W7214023393
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Stacy G. Beal, Anissa Naranjo, Carlos Torres, Claire Carter, Joyce Chen, Michael Rummel, Jenny Trau, Breland Hockman |
| Journal | the journal of applied laboratory medicine |
| Year | 2026 |
| DOI |
10.1093/jalm/jfag145
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.